OPC UA Server Plug-In for OPC Router - License type: Subscription license for 1 year

OPC UA Server Plug-In for OPC Router - License type: Subscription license for 1 year


Inray

This OPC Router plug-in enables the OPC Router to offer OPC Router's variables to OPC UA clients via the OPC UA protocol. Any value from any system connected to the OPC Router can be stored in OPC Router's variables. In the OPC Router, data can be mathematically processed. This plug-in is an OPC Router accessory. Más

Código del producto: OPCR-OPCSER-SUB-PROD

465 EUR sin IVA (562,65 EUR IVA incl.)
La variante no existe
En stock
pcs
(0 pcs En stock)

Rezervace termínu

Solicitar presupuesto

Inray

This OPC Router plug-in enables the OPC Router to offer OPC Router's variables to OPC UA clients via the OPC UA protocol. Any value from any system connected to the OPC Router can be stored in OPC Router's variables. In the OPC Router, data can be mathematically processed. This plug-in is an OPC Router accessory. Más

Código del producto: OPCR-OPCSER-SUB-PROD

Opciones 9

License type Código Disponibilidad Precio sin IVA
Subscription license for 1 year OPCR-OPCSER-SUB-PROD En stock
465 EUR
Subscription license for 2 years OPCR-OPCSER-SUB-PROD 2x En stock
930 EUR
Subscription license for 3 years OPCR-OPCSER-SUB-PROD 3x En stock
1 395 EUR
Perpetual (permanent) license with 1 year support OPCR-OPCSER-PRP-PROD + OPCR-OPCSER-ATT-PROD En stock
1 081 EUR
Perpetual license with 2 years support OPCR-OPCSER-PRP-PROD + OPCR-OPCSER-ATT-PROD + OPCR-OPCSER-EXT-PROD En stock
1 283 EUR
Perpetual license with 3 years support OPCR-OPCSER-PRP-PROD + OPCR-OPCSER-ATT-PROD + 2x OPCR-OPCSER-EXT-PROD En stock
1 485 EUR
Perpetual license support extension for 1 year OPCR-OPCSER-EXT-PROD 1x En stock
202 EUR
Perpetual license support extension for 2 years OPCR-OPCSER-EXT-PROD 2x En stock
404 EUR
Perpetual license support extension for 3 years OPCR-OPCSER-EXT-PROD 3x En stock
606 EUR

OPC Router is a software program that allows you to connect data from various industrial devices and IT/OT systems to each other. All this quickly, automatically and without programming knowledge. In addition, you can see all data flows in a clear visualization.  

Collect data, connect systems, perform calculations, compare values and enter results into databases. You can do all this with OPC Router for PLC systems, OPC servers, printers, RFID readers, emails, Excel spreadsheets, databases, cloud systems, MQTT brokers, ERP systems SAP R3, SAP HANA, etc. For installation on a single computer you need a basic module and one or more plug-in modules.

OPC UA Server Plug-In

The OPC UA protocol is widely used in industrial communications. The OPC Router allows you to connect various IT and OT systems to it and exchange data between them. With the OPC UA Server plug-in installed, the OPC Router can act as OPC UA Server and provide data for other OPC UA systems.

In the OPC Router schema below, you can see many different devices and systems connected to the OPC Router, using the OPC Router for exchanging data between each other. These systems include, among others, Euromap, SAP/ERP, IIoT, databases, readers, printers, RFID and KEPServerEX. Any data can be stored in OPC Router's internal variables. This data is then available and accessible to other systems and can be read out by OPC UA clients. In other words, the OPC Router with the OPC UA Server plug-in installed can offer data to the outside world through the OPC UA protocol.

Providing database data via the OPC UA protocol

Imagine the following scenario. In the OPC Router, you have enabled the OPC UA Server and are storing data from a database in OPC Router's internal variables. You are also reading out this data using KEPServerEX's OPC UA Client driver. To check that you are reading this data from the OPC UA Server correctly, you utilise the OPC Quick Client.

Let us now explore this in more detail. Every 30 seconds data is automatically (1) read out from the database (2) and written to OPC Router's internal variables (3). On the arrows (4), you can see values of individual variables being transferred. In the graph (5), which acts as a monitoring and diagnostic tool, you can see several green dots. Each of them means that a connection has been triggered. If a problem occurs in any of the connections, the green dot turns red and an error is reported.

 

 

Using KEPServerEX's OPC connectivity (i.e. through its OPC UA Client driver) you have read out data from OPC Router's OPC UA Server and transferred it to KEPServerEX. In the picture below, you can see KEPServerEX's OPC Quick Client, through which you have checked that the data transfer works and that data from the OPC Router (i.e. from the database) has been read out successfully (6).

 

 

Setting the OPC UA Server in OPC Router

Requisitos del sistema

Instalación y actualización

El paquete de instalación de OPC Router instala el entorno de configuración, los servicios de Windows y todos los plug-ins en modo demo con un tiempo de ejecución de 2 horas. Los plug-ins licenciados solo pueden ejecutarse sin límite de tiempo después de introducir la clave de licencia.

La instalación no incluye ningún sistema de base de datos ni servidor OPC para uso en producción. Estos componentes deben instalarse por separado y luego conectarse en la configuración de OPC Router.

Rendimiento del ordenador

OPC Router es una aplicación de servidor, por lo que recomendamos ejecutarlo en un hardware adecuado. Para una implementación habitual, recomendamos:

  • procesador multinúcleo,
  • mínimo 8 GB de RAM,
  • almacenamiento SSD.

Sistema operativo

Para el uso en producción recomendamos sistemas operativos Microsoft Windows Server. También se pueden utilizar sistemas operativos cliente de 64 bits, especialmente para pruebas.

Sistemas operativos compatibles:

  • Windows Server 2016 x64
  • Windows Server 2019 x64
  • Windows Server 2022 x64
  • Windows Server 2025 x64
  • Windows 10 x64
  • Windows 10 IoT x64
  • Windows 11 x64

Ejecución en Docker

OPC Router también puede ejecutarse en un contenedor Docker, por ejemplo en un dispositivo Edge o en un dispositivo con Windows. Los requisitos mínimos para ejecutarlo en un contenedor Docker son:

  • procesador de un solo núcleo de 64 bits a 600 MHz con soporte AVX,
  • 512 MB de RAM,
  • 3 GB de espacio libre en disco.

.NET 8

OPC Router requiere el entorno .NET 8. Si no está instalado en el sistema, la instalación de OPC Router lo instalará si es necesario.

En entornos de producción recomendamos instalar .NET 8 manualmente desde Microsoft antes de actualizar OPC Router. La instalación de .NET puede requerir actualizaciones de Windows, tardar más tiempo y, en algunos casos, requerir varios reinicios. Para reducir el tiempo de parada, recomendamos desinstalar las versiones anteriores de .NET solo después de que .NET 8 se haya instalado correctamente.

Servidor OPC

Para conectar sistemas de control mediante OPC, debe estar disponible un servidor OPC instalado y accesible. OPC Router admite conexiones mediante OPC DA 4.0, OPC UA y OPC XML.

Para la comunicación con un servidor OPC se requiere el plug-in OPC correspondiente.

Servidor de base de datos y fuentes de datos

Los servidores de bases de datos no forman parte de la instalación de OPC Router. Si desea conectarlos con OPC Router, deben instalarse y ponerse a disposición por separado.

OPC Router admite la conexión con los siguientes sistemas de bases de datos e interfaces:

  • Microsoft SQL Server
  • Oracle
  • MySQL
  • SAP HANA
  • OLE DB
  • sistemas accesibles mediante ODBC

También es posible conectar las siguientes bases de datos, fuentes de datos o archivos:

  • MS Access
  • SQLite
  • dBase
  • InfluxDB
  • MongoDB
  • archivos XML

Los plug-ins para la comunicación con bases de datos no están incluidos en la licencia Basic. Para cada tipo concreto de conexión a base de datos, es necesario seleccionar el plug-in correspondiente.

Conexión a base de datos Oracle

Para conectarse a una base de datos Oracle, es necesario tener instalado Oracle Instant Client (ODAC).

SAP Plug-in

El SAP Plug-in es compatible con sistemas SAP versión 4.0b o superior. En el ordenador con OPC Router debe estar instalado SAP Logon Pad o la biblioteca librfc32.dll.

Para utilizar SAP NetWeaver, es necesario instalar SAP NetWeaver RFC SDK.

El SAP Plug-in es un módulo con licencia independiente y no está incluido en la licencia Basic.