RFID-AutoID (OPC UA) Plug-In for OPC Router - License type: Subscription license for 1 year
This OPC Router plug-in allows you to connect OPC UA-compatible RFID readers with AutoID to various OT and IT systems. The plug-in is an OPC Router accessory. More
Code: OPCR-RFID00-SUB-PROD
This OPC Router plug-in allows you to connect OPC UA-compatible RFID readers with AutoID to various OT and IT systems. The plug-in is an OPC Router accessory. More
Code: OPCR-RFID00-SUB-PROD
Options 9
| License type | Code | Verfügbarkeit | Price Exkl. MwSt. | |
|---|---|---|---|---|
| Subscription license for 1 year | OPCR-RFID00-SUB-PROD | In stock |
465 EUR
|
|
| Subscription license for 2 years | OPCR-RFID00-SUB-PROD 2x | In stock |
930 EUR
|
|
| Subscription license for 3 years | OPCR-RFID00-SUB-PROD 3x | In stock |
1 395 EUR
|
|
| Perpetual (permanent) license with 1 year support | OPCR-RFID00-PRP-PROD + OPCR-RFID00-ATT-PROD | In stock |
1 081 EUR
|
|
| Perpetual license with 2 years support | OPCR-RFID00-PRP-PROD + OPCR-RFID00-ATT-PROD + OPCR-RFID00-EXT-PROD | In stock |
1 283 EUR
|
|
| Perpetual license with 3 years support | OPCR-RFID00-PRP-PROD + OPCR-RFID00-ATT-PROD + 2x OPCR-RFID00-EXT-PROD | In stock |
1 485 EUR
|
|
| Perpetual license support extension for 1 year | OPCR-RFID00-EXT-PROD 1x | In stock |
202 EUR
|
|
| Perpetual license support extension for 2 years | OPCR-RFID00-EXT-PROD 2x | In stock |
404 EUR
|
|
| Perpetual license support extension for 3 years | OPCR-RFID00-EXT-PROD 3x | In stock |
606 EUR
|
OPC Router is a software program that allows you to connect data from various industrial devices and IT/OT systems to each other. All this quickly, automatically and without programming knowledge. In addition, you can see all data flows in a clear visualization.
Collect data, connect systems, perform calculations, compare values and enter results into databases. You can do all this with OPC Router for PLC systems, OPC servers, printers, RFID readers, emails, Excel spreadsheets, databases, cloud systems, MQTT brokers, ERP systems SAP R3, SAP HANA, etc. For installation on a single computer you need a basic module and one or more plug-in modules.
RFID-AutoID OPC UA Plug-In
Working with RFID readers has long been characterised by manufacturer-specific protocols and connection types. With the OPC UA AutoID Companion Specification, this has now changed fundamentally. In the specification, communication with the reader is standardised and the communication protocol is set to OPC UA. Thus, manufacturer independence is achieved on the application side.
The OPC Router implements the RFID part of the AutoID specification and is therefore able to easily connect compatible RFID readers and integrate them into Industry 4.0 environments. AutoID-compatible readers are available, for example, from Harting, Siemens and TURCK.

Transferring the RFID code to the PLC
RFID readers that support the Auto ID Companion Specification provide the RFID code read in a standardised way. With the appropriate OPC Router plug-in, this code can be passed on to any system. For direct process control based on the identification, the code can be transferred directly to the controller (PLC) with the OPC UA Client plug-in.
System Requirements
Installation and Update
The OPC Router setup installs the configuration environment, Windows services and all plug-ins in demo mode with a runtime of 2 hours. Licensed plug-ins can only be run without time limitation after entering the license key.
The installation does not include a database system or an OPC server for production use. These components must be installed separately and then connected in the OPC Router configuration.
Computer Performance
OPC Router is a server application, so we recommend running it on suitable hardware. For standard use, we recommend:
- a multi-core processor,
- at least 8 GB RAM,
- SSD storage.
Operating System
For production use, we recommend Microsoft Windows Server operating systems. 64-bit client operating systems can also be used, especially for testing purposes.
Supported operating systems:
- Windows Server 2016 x64
- Windows Server 2019 x64
- Windows Server 2022 x64
- Windows Server 2025 x64
- Windows 10 x64
- Windows 10 IoT x64
- Windows 11 x64
Running in Docker
OPC Router can also be run in a Docker container, for example on an Edge device or a Windows device. The minimum requirements for running OPC Router in a Docker container are:
- 64-bit single-core 600 MHz CPU with AVX support,
- 512 MB RAM,
- 3 GB of free disk space.
.NET 8
OPC Router requires .NET 8. If it is not installed on the system, the OPC Router setup will install it if necessary.
In production environments, we recommend installing .NET 8 manually from Microsoft before updating OPC Router. The .NET installation may require Windows updates, take longer to complete and sometimes require several restarts. To reduce downtime, we recommend uninstalling older .NET versions only after .NET 8 has been installed successfully.
OPC Server
To connect controllers via OPC, an installed and accessible OPC server must be available. OPC Router supports connections via OPC DA 4.0, OPC UA and OPC XML.
The corresponding OPC plug-in is required for communication with an OPC server.
Database Server and Data Sources
Database servers are not part of the OPC Router installation. If you want to connect them to OPC Router, they must be installed and made accessible separately.
OPC Router supports connections to the following database systems and interfaces:
- Microsoft SQL Server
- Oracle
- MySQL
- SAP HANA
- OLE DB
- systems accessible via ODBC
The following databases, data sources or files can also be connected:
- MS Access
- SQLite
- dBase
- InfluxDB
- MongoDB
- XML files
Plug-ins for database communication are not included in the Basic license. The appropriate plug-in must be selected for the specific type of database connection.
Oracle Database Connection
To connect to an Oracle database, Oracle Instant Client (ODAC) must be installed.
SAP Plug-in
The SAP Plug-in supports SAP systems version 4.0b and higher. SAP Logon Pad or the librfc32.dll library must be installed on the computer running OPC Router.
To use SAP NetWeaver, SAP NetWeaver RFC SDK must be installed.
The SAP Plug-in is a separately licensed module and is not included in the Basic license.

New features in the OPC Router 5.1 data hub
The new version of OPC Router 5 brings some big changes. The biggest change is the user interface, which brings the user more comfort when working with the program and the ability to work in Linux, macOS, etc. There are also new options for creating user accounts, improvements in application performance optimization and many other improvements.
Highlighted items are mandatory.