ALTA Industrial Wireless Three Phase Current Meter – 150 Amp

he ALTA Industrial Wireless Three Phase Current Meter (150 Amp) measures the RMS current of an alternating current (AC) system using 3 current transformers (CTs) that wrap around the wires of a three phase power system.The sensor reports Minimum RMS current, maximum RMS current, average RMS current, and duty cycle for each phase and the combined amp hours of all three phases to the iMonnit system.

Manufacturer
Monnit

Configure product

Power supply
Standard
Solar rechargeable battery
Antenna
Standard (Di-pole SMA)
High Gain Leaded Puck

Configure product

Nastavit výchozí kombinaci

624 €

624 €

Information

The ALTA Industrial Wireless Three Phase Current Meter measures the RMS current of an alternating current (AC) system using 3 current transformers (CTs) that wrap around the wires of a three phase power system. The sensor reports Minimum RMS current, maximum RMS current, average RMS current, and duty cycle for each phase and the combined amp hours of all three phases to the iMonnit system. The iMonnit system is capable of generating watt hour or kilowatt hour readings as well based on a user specified RMS voltage.

  • Measures amp hours, max RMS current, min RMS current, average RMS current, and duty cycle for each phase and combined amp hours from all three phases 
  • 3 x 0-150 amp current transducers 
  • Capable of generating watt hour or kilowatt hour readings using iMonnit
  • Data logging for accumulated amp hour readings 
  • Can notify based on current levels 
  • Simple and safe installation of current/power measurement hardware, no rewiring required

To measure current, clip the CT around only a single wire of a powered system (clipping around a hot and neutral wire at the same time will result in 0 current readings). After the sensor powers on and connects to the gateway it will begin taking measurements based on the averaging interval (5 seconds default). It will report data to iMonnit every heartbeat or if the current goes outside of the aware thresholds set in iMonnit. The sensor reports average current, max RMS current, min RMS current, and duty cycle for each phase and amp hours for all three phases combined. iMonnit can also generate watt hour or kilowatt hour readings if a default RMS voltage is set in iMonnit.

* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables. Other power options are also available

Download

Other

NameTypeVersionSizeDescriptionDownload
Case studypdf1.60 MB

"Manual temperature measurement in halls is obsolete and inefficient," says Třinecké železárny, a.s. only Czech

Features

Absolute Max CT Current

200 Amps RMS (Arms)

Maximum Accurate CT Current

150 Arms

Frequency Measurement Range

50–100 Hz

Accuracy

+/- 2% @ 2 to 150 Arms, +/- 0.4 Arms @ < 15 Arms

Calibrated Accuracy with Appropriate Offset

+/- 1% @ 2 to 150 Arms, +/- 0.2 Arms @ < 2 Arms

Offset Limits

-1.27 to + 1.27 Arms (default set to +0.3 Arms)

Measurement Resolution

Average: 0.01 Arms

Max: 1 Arms

Min: 1 Arms

Duty: 1%

Amp Hours: 0.1 Amp Hours

Dimension

67 mm x 49 mm x 42 mm (24 mm inner diameter)

Weight

28.7 oz.

UL Rating

UL Listed to UL508-4x specifications (File E194432)

ALTA Industrial Specifications

Supply Voltage

2.0 - 3.8 VDC

Battery Type

Replaceable 3.6V, 1800mAH (single AA sized)

Battery Life

Up to 10 Year Battery Life.**

Max Operating Temperature

-40° to 85°C (-40° to 185°F)

Optimal Battery Operating Temperature

+10°C to +50°C (+50°F to +122°F)

Solar Power Option

3.0 VDC Solar Panel 

600 mAH Rechargeable Battery (>2000 Charge Cycles - 80% of Initial Capacity)

Charging Temperature Range: 0° to 45°C (32° to 113°F)

Max Temperature Range: -20° to 60°C (-4° to 140°F)

Enclosure Material

IP65, NEMA 4X, CE rated, sealed, weatherproof enclosure

UL Rating

UL Listed to UL508-4x specifications (File E194432)

Dimension

3.7 in x 2.32 in x 1.38 in

ALTA 868 MHz Specifications

Operating Frequency

868 MHz Operating Frequency

Certifications

CE Certified. Tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950.

Security

Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC)

Device Range

Device Range Up to 1,200 ft. non-line-of-sight, wireless device range*

Video Monnit

Jak vyměnit baterie v sensorech ALTA Začleňte IoT do vaší malé firmy 
Vytvoření účtu v portálu iMonnit Vytváření událostí v portálu iMonnit 
Jak si zakoupit předplatné portálu iMonnit Exportování CSV souborů 
Nastavení událostí Prodloužení předplatného portálu iMonnit 
Introducing the Monnit ALTA Industrial 4G LTE Cellular GatewayAdding Devices on iMonnit
Creating iMonnit ActionsCreating An iMonnit Account
Editing iMonnit ActionsiMonnit Actions for Open & Closed Sensors
Basic iMonnit Actions for Refrigeration SystemsiMonnit Actions for Water Detection Systems
Advanced iMonnit Actions for Refrigeration SystemsMounting the Advanced Vibration Meter
Aware States within iMonnitiMonnit Heartbeats Explained
iMonnit Main Menu Navigation OverviewReplacing Monnit Sensor Batteries
Introducing the Monnit ALTA Industrial Propane MonitorMonnit ALTA Sensor Settings in iMonnit
Installing a Monnit ALTA Temperature SensorsIntroducing the Monnit ALTA Industrial Vehicle Detection Counter
Installing the Monnit ALTA Open/Closed SensorInstalling the Monnit ALTA Water Puck Sensor
Generating an Access Token within iMonnit

Accessories

Viewed products

Quick enquiry
close