CANtouch® – a pocket tester for CAN bus, CANopen, DeviceNet & SAE J1939 Networks

CANtouch® – a pocket tester for CAN bus, CANopen, DeviceNet & SAE J1939 Networks


Portable tester for analysis and diagnostics of CAN, CANopen, DeviceNet and SAE J1939 networks without the use of a PC. Suitable for measuring network status, faults, voltages, CAN levels, checking cabling and devices. Generates reports from the measurements. Size and touch control is similar to a smart phone. More

Manufacturer: GEMAC Code: PR-22580-81

3 340 EUR excl. VAT (4 041,40 EUR incl. VAT)
Recycling fee 0,016 EUR v cene.
Delivery 3-8 days
pcs

Portable tester for analysis and diagnostics of CAN, CANopen, DeviceNet and SAE J1939 networks without the use of a PC. Suitable for measuring network status, faults, voltages, CAN levels, checking cabling and devices. Generates reports from the measurements. Size and touch control is similar to a smart phone. More

Manufacturer: GEMAC Code: PR-22580-81

The CANtouch is a handheld, battery-powered diagnostic tool for physical as well logical analysis of CANbus systems. With its modern touch controls, it allows intuitive, efficient handling without an additional computer.

As a follow-up to the CANbus Tester 2, it doesn't only feature its predecessor's functionality, but it has new additional measurement capabilities. The analyser provides a quick overview of your network's health via a mix of traffic lights and smileys. It has an integrated update capability which allows further enhancements. New functionalities can be unlocked by purchasing additional licenses.

 

Features

  • Supports CAN, CANopen, DeviceNet & SAE J1939 bus systems
  • Supported baud rates: 10 kBit/s – 1 Mbit/s
  • App-supported measurement:
    • Bus traffic load
    • Active and passive error frames
    • CAN supply voltage and shield voltage
    • Common mode voltage
    • CAN level (absolute / differential)
    • Short circuits, interruptions, loop resistances & cable length
    • Nodes (quality level, disturbance-free voltage range, edge steepness & oscilloscope display)
    • Protocol monitor (send and receive of CAN messages including symbolic decoding and long-term trace)
  • Includes 6 applications + another 3 apps when you purchase additional licences

 

CANtouch - ruční diagnostický nástroj pro sítě CAN, CANopen, DeviceNet a SAE J1939

General parameters and overview of functions
Languages: German, Englisch
Bus systems: CAN (ISO11898‑2), CANopen (CiA301), DeviceNet (EN 50325 – 2), SAE J1939
Bit sampling : 64-fold, 10240 sampling points
Bit timing: Adjustable BTL cycles (tq), sample point and resynchronization jump width (SJW)
Supported baud rates Depending on bus system: 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s
Additionally user-defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s
Automatic detection via baud rate scan, bit timing adjustable
Bus status Bus traffic detection (display: dominant, recessive, not defined, bus traffic)
Display of the Bus traffic load (0 … 100 %)
characteristic, minimum and maximum value saving
Bus errors Display of detected frame errors
Distinction between active and passive error frames (0 … >50,000), trend chart
Bus voltages Display of the optional CAN supply voltage and shield voltage
Characteristic, minimum and maximum value saving
Common mode voltage Acquisition of the maximum voltage offset between the individual bus nodes
CAN level (absolute /differential) Acquisition and evaluation of the differential and absolute CAN levels of all bus nodes during operation
Node measurement Node related measurements
Quality value (signal quality), Disturbance-free voltage range, Edge steepness (falling
and rising) and Oscilloscope display with message frame analysis
Online Trigger Error analysis with adjustable values, variable time slices and trigger function
Protocol monitor Send and receive of CAN messages

Electrical parameters
Power supply and battery* Integrated, rechargeable lithium-ion battery
External power input: SELV d.c. voltage 14 V, internal fused with 2.5 A
Operating with the supplied 35 W wide-range power supply unit only (SAW-14.0 – 2500)
Times-to-empty: Standby: up to 500 hours
Use: up to 36 hours
Measuring: up to 6 hours
Charge times: Quick charge to 80% in approx. 1 h
Full charge in approx. 2 h
Potential difference between the CAN bus and USB connections < 500 V AC
Voltage between any two terminals of the CAN connection or external ground, resp. < ±30 V DC

Measurements
Range Resolution Accuracy (typ.)
Quality value 0,0 % … 100,0 % 0,1 % -
Edge steepness 0/64 … 64/64 1/64 -
Disturbance-free voltage range -0,75 V … +3,25 V 0,05 V 1,90 % ±100 mV
Measuring of the differential voltage -0,75 V … +3,25 V 0,01 V 0,50 % ±10 mV (calibrated)
Measuring of the absolute voltage -5,00 V … +10,00 V 0,05 V 0,50 % ±50 mV (calibrated)
Measuring of the shield voltage -10,0 V … +1,0 V 0,1 V 0,25 % ±100 mV (calibrated)
Measuring of the CAN supply voltage 0.0 V … 32,0 V 0,1 V 0,25 % ±100 mV (calibrated)
Measuring of the loop resistances 0 Ω … 100 Ω
100 Ω … 1000 Ω
0,1 Ω
1,0 Ω
0,85 % ±0,2 Ω
0,85 % ±2,0 Ω
Measuring of the cable length 2 m … 1000 m 1 m 5 % ±2 m
(signal propagation delay: 4.5 ns/m)

Mechanical parameters
Power supply unit connection Extra-low voltage socket
CAN connection 9‑pin D‑Sub connector
PC connection Self-powered device to USB Specification 2.0, full speed, in addition, electrically isolated
Connection of a drive for exchange of measuring data (USB mass storage device)
Housing Aluminum housing, cover glass
Ambient conditions Operation temperature: 5 °C … 40 °C
Storage temperature: ‑20 °C … 60 °C
Atmospheric humidity: 20 % … 80 %, non-condensing
Degree of protection of the housing IP20 to EN 60529
Dimensions 186 mm x 102 mm x 37 mm
Weight Approx. 860 g