Deltalogic OPC DA Server for Siemens Simatic S7 / S5 - Type: USB dongle HW license

Deltalogic OPC DA Server for Siemens Simatic S7 / S5 - Type: USB dongle HW license


The Deltalogic OPC Server enables OPC DA communications between the Siemens SIMATIC S7-200, S7-1200, S7-300, S7-400, S7-1500, LOGO! 0BA7/0BA8, S5 PLC controllers and OPC client applications, via such protocols as the TCP/IP, MPI, PROFIBUS and PPI. It supports the import of variables from the STEP7. More

Manufacturer: Delta Logic Code: 140002WUX

1 035 EUR excl. VAT (1 252,35 EUR incl. VAT)
Variant does not exist
In stock
pcs

The Deltalogic OPC Server enables OPC DA communications between the Siemens SIMATIC S7-200, S7-1200, S7-300, S7-400, S7-1500, LOGO! 0BA7/0BA8, S5 PLC controllers and OPC client applications, via such protocols as the TCP/IP, MPI, PROFIBUS and PPI. It supports the import of variables from the STEP7. More

Manufacturer: Delta Logic Code: 140002WUX

Variants2

Type Availability Price excl. VAT Quantity (pcs)
Deltalogic OPC DA Server for Siemens Simatic S7 / S5 - Type: USB dongle HW license Software license In stock More 1 035 EUR
Deltalogic OPC DA Server for Siemens Simatic S7 / S5 - Type: USB dongle HW license USB dongle HW license In stock More 1 035 EUR

The Deltalogic OPC Server for the Siemens Simatic S5/S7 PLCs is a software program that allows you to transfer data (i.e. to perform read/write operations) from the Siemens SIMATIC S7-1500, S7-1200, S7-200, S7-300, S7- 400, LOGO!, WinAC PLC, C7 and M7 controllers to OPC client, via the OPC protocol.

The Deltalogic OPC Server enables communication with the Simatic S7-200/-300/-400 PLCs via Ethernet through the ACCON NetLink PRO adapter. The adapter is the perfect TCP/IP adapter for the Simatic PLCs that don't have the TCP/IP interface (they must have a free MPI/PROFIBUS/PPI port).

The Deltalogic OPC DA Server supports the import of variables from STEP7 projects. If you have your STEP7 project at your disposal, simply import it into the server. You'll then be able to display all configured addresses in it and perform read/write operations in OPC client. The list of all the addresses can further be edited in the .TXT file.

Please note: If you're going to create or edit OPC items in an alias file, we recommend that you follow the instructions in Online Help (the chapter Syntax Items). In some cases, there can be an I/O communication problem as the server supports German terminology (E/A) instead of English terminology (I/O) – e.g. I2.0 = E2.0, IB2 = EB2, Q1.0 = A1.0, QB1 = AB1.

Deltalogic OPC Server Licencing:

The Deltalogic OPC Server can be licenced via a hardware key or a software licence.

If possible, we recommend the hardware key as it allows licence transfer to another computer.

The software licence can't be transferred to another PC. If there is a machine failure, you can have your licence restored. (Important: Deltalogic provides only 2 instances of such licence restore).

Migration from a software licence to a hardware key is supported by version 4.1x only.

Migration from version 3.x/4.0 to 4.1x is only possible within 5 years of purchasing a licence.

 

IMPORTANT: As of 2013, there is different Deltalogic OPC Server Licencing. The versions below are NOT compatible.

  • Deltalogic OPC Server v4.1x (the current version – only these Product IDs: 140002WAX, 140002WUX)
  • Deltalogic OPC Server v4.0.6 (a version with an older core – only these Product IDs: 917910-W32, 917910-W32-U)
Supported operating systems Windows XP, 7, 8.1, 2008 R2, 2012 R2 (32 and 64 bit), 2016, 2019
Supported PLCs S5, S7-200, S7-1200, S7-300, S7-400, S7-1500, LOGO! 0BA7 & 0BA8, S7-300/400-compatible PLCs (e.g. Vipa, Saia, Berthel)
Supported OPC specifications Data Access 1.0a, 2.05, 3.0 und OPC-XML-DA
Supported OPC interfaces All Mandatory Interfaces according to Data Access specification
Dynamic namespace with STEP 7 semantics for OPC item names
Static namespace by importing symbols from STEP 7 or text file
Supported OPC data types VARIANT data types UI1, I1, UI2, I2, UI4, I4, R4, R8, BOOL as well as arrays including these data types, BSTR
Supported S7 data types BOOL, BYTE, CHAR, WORD, INT, BCD, S5TIME, DATE, DWORD, DINT, REAL, TIME, TIME_OF_DAY, DATE_AND_TIME as well as fields with these data types, STRING
Supported S7 operand types I, Q, M, C, T, DB, PE, PA
Forms of implementation OutProc Server, Service
Number of PLCs Min. 256, with TCP/IP up to 4096

Supported communication channels

PLC interface PC interface
TCP/IP USB RS-232 Siemens CP
S7-300/400 via MPI ACCON-NetLink-PRO compact ACCON-NetLink-USB compact ACCON-MPI-Adapter RS-232 +
S7-300/400 via PROFIBUS ACCON-NetLink-PRO compact ACCON-NetLink-USB compact - +
S7-300/400 via TCP/IP (PN/IE) + - - +
S7-200 via PPI ACCON-NetLink-PRO compact ACCON-NetLink-USB compact ACCON-PPI-Adapter +
S7-200 via TCP/IP + - - +
S5 via PG bushing (AS511) ACCON-S5-LAN
ACCON-COM-Kabel IE
ACCON-COM-Cable USB ACCON-COM-Cable
ACCON-COM-Adapter
-
S5 via TCP/IP1) + - - -
S7-1200 via TCP/IP + - - -
S7-1500 via TCP/IP + - - -
LOGO! 0BA7/0BA8 via TCP/IP + - - -

+ Possible without adapter
- Not possible

1) Siemens CP 1430 TCP, VIPA CP143 TCP/IP, INAT S5-TCP/IP 100

Alternative products2