Deltalogic OPC DA Server for Siemens Simatic S7 / S5 - Type: USB dongle HW license
- OPC Server, OPC Router
- OPC Servers DELTALOGIC
- Deltalogic OPC DA Server for Siemens Simatic S7 / S5
Deltalogic OPC DA Server for Siemens Simatic S7 / S5 - Type: USB dongle HW license
The Deltalogic OPC Server enables OPC DA communications between the Siemens SIMATIC S7-200, S7-1200, S7-300, S7-400, S7-1500, LOGO! 0BA7/0BA8, S5 PLC controllers and OPC client applications, via such protocols as the TCP/IP, MPI, PROFIBUS and PPI. It supports the import of variables from the STEP7. More
Manufacturer: Delta Logic Code: 140002WUX
The Deltalogic OPC Server enables OPC DA communications between the Siemens SIMATIC S7-200, S7-1200, S7-300, S7-400, S7-1500, LOGO! 0BA7/0BA8, S5 PLC controllers and OPC client applications, via such protocols as the TCP/IP, MPI, PROFIBUS and PPI. It supports the import of variables from the STEP7. More
Manufacturer: Delta Logic Code: 140002WUX
The Deltalogic OPC Server for the Siemens Simatic S5/S7 PLCs is a software program that allows you to transfer data (i.e. to perform read/write operations) from the Siemens SIMATIC S7-1500, S7-1200, S7-200, S7-300, S7- 400, LOGO!, WinAC PLC, C7 and M7 controllers to OPC client, via the OPC protocol.
The Deltalogic OPC Server enables communication with the Simatic S7-200/-300/-400 PLCs via Ethernet through the ACCON NetLink PRO adapter. The adapter is the perfect TCP/IP adapter for the Simatic PLCs that don't have the TCP/IP interface (they must have a free MPI/PROFIBUS/PPI port).
The Deltalogic OPC DA Server supports the import of variables from STEP7 projects. If you have your STEP7 project at your disposal, simply import it into the server. You'll then be able to display all configured addresses in it and perform read/write operations in OPC client. The list of all the addresses can further be edited in the .TXT file.
Please note: If you're going to create or edit OPC items in an alias file, we recommend that you follow the instructions in Online Help (the chapter Syntax Items). In some cases, there can be an I/O communication problem as the server supports German terminology (E/A) instead of English terminology (I/O) – e.g. I2.0 = E2.0, IB2 = EB2, Q1.0 = A1.0, QB1 = AB1.
Deltalogic OPC Server Licencing:
The Deltalogic OPC Server can be licenced via a hardware key or a software licence.
If possible, we recommend the hardware key as it allows licence transfer to another computer.
The software licence can't be transferred to another PC. If there is a machine failure, you can have your licence restored. (Important: Deltalogic provides only 2 instances of such licence restore).
Migration from a software licence to a hardware key is supported by version 4.1x only.
Migration from version 3.x/4.0 to 4.1x is only possible within 5 years of purchasing a licence.
IMPORTANT: As of 2013, there is different Deltalogic OPC Server Licencing. The versions below are NOT compatible.
- Deltalogic OPC Server v4.1x (the current version – only these Product IDs: 140002WAX, 140002WUX)
- Deltalogic OPC Server v4.0.6 (a version with an older core – only these Product IDs: 917910-W32, 917910-W32-U)
Supported operating systems | Windows XP, 7, 8.1, 2008 R2, 2012 R2 (32 and 64 bit), 2016, 2019 |
Supported PLCs | S5, S7-200, S7-1200, S7-300, S7-400, S7-1500, LOGO! 0BA7 & 0BA8, S7-300/400-compatible PLCs (e.g. Vipa, Saia, Berthel) |
Supported OPC specifications | Data Access 1.0a, 2.05, 3.0 und OPC-XML-DA |
Supported OPC interfaces | All Mandatory Interfaces according to Data Access specification Dynamic namespace with STEP 7 semantics for OPC item names Static namespace by importing symbols from STEP 7 or text file |
Supported OPC data types | VARIANT data types UI1, I1, UI2, I2, UI4, I4, R4, R8, BOOL as well as arrays including these data types, BSTR |
Supported S7 data types | BOOL, BYTE, CHAR, WORD, INT, BCD, S5TIME, DATE, DWORD, DINT, REAL, TIME, TIME_OF_DAY, DATE_AND_TIME as well as fields with these data types, STRING |
Supported S7 operand types | I, Q, M, C, T, DB, PE, PA |
Forms of implementation | OutProc Server, Service |
Number of PLCs | Min. 256, with TCP/IP up to 4096 |
Supported communication channels
PLC interface | PC interface | |||
TCP/IP | USB | RS-232 | Siemens CP | |
S7-300/400 via MPI | ACCON-NetLink-PRO compact | ACCON-NetLink-USB compact | ACCON-MPI-Adapter RS-232 | + |
S7-300/400 via PROFIBUS | ACCON-NetLink-PRO compact | ACCON-NetLink-USB compact | - | + |
S7-300/400 via TCP/IP (PN/IE) | + | - | - | + |
S7-200 via PPI | ACCON-NetLink-PRO compact | ACCON-NetLink-USB compact | ACCON-PPI-Adapter | + |
S7-200 via TCP/IP | + | - | - | + |
S5 via PG bushing (AS511) | ACCON-S5-LAN ACCON-COM-Kabel IE |
ACCON-COM-Cable USB | ACCON-COM-Cable ACCON-COM-Adapter |
- |
S5 via TCP/IP1) | + | - | - | - |
S7-1200 via TCP/IP | + | - | - | - |
S7-1500 via TCP/IP | + | - | - | - |
LOGO! 0BA7/0BA8 via TCP/IP | + | - | - | - |
+ Possible without adapter
- Not possible
1) Siemens CP 1430 TCP, VIPA CP143 TCP/IP, INAT S5-TCP/IP 100
Highlighted items are mandatory.